Syntegra
XT Series
Flush Exit Device Openings
The flagship of Syntégra’s integrated door systems is the XT Series, which combines the functionality of a mortise lockset with the free-egress safety features of an exit device.
Building owners no longer have to sacrifice aesthetics for strength and durability because Syntégra engineers their door systems to be configurable and adaptable to meet the needs of the each opening. Finally, a ‘no compromise’ solution that looks as great as it performs.
The sleek yet balanced near-flush exit device recesses into the door face to maximize the clear opening width for a safe and accessible path of egress while complying with the strictest fire and life safety codes. Plus, the robust mechanisms and electrical functions are engineered to meet the most demanding and punishing commercial, educational, institutional, and industrial environments.

TECHNICAL INFORMATION
downloads and details
Customer-Favourite Commercial Rollup Doors
Depending on your needs, we have an extensive selection of high-performance, energy-efficient and fire-rated products to choose from, including the following.
SECURE ROLLUP GARAGE DOORS
If you want top performance and high-speed operation, our high-performance security doors will have you covered. These doors are among the best overhead door investments with some of the lowest overall lifetime costs:
- Extreme® 300 Series High-Performance Rollup Door: This springless series door is high-speed and intelligent thanks to the Apex SmartController. Designed to last 300,000 maintenance-free cycles, the Extreme 300 has it all.
- Extreme® 1024 Long-Lasting Rollup Door: The Extreme 1024 high-performance rapid-roll door offers intelligent Apex SmartController operation and can withstand an impressive 1,000,000 maintenance-free cycles.
- StormDefender™ Safe Room Door: This commercial rollup door is designed explicitly with security and life safety in mind, guarding you and your building against tornadoes, hurricanes and other severe weather.
- EntryDefender™ High-Security Door: The EntryDefender™ Door meets the U.S. Department of State Standard for forced entry for a five-, 15- and 60-minute mob-style attack.
FIRE-RATED ROLLUP SERVICE DOORS
Rollup fire doors are rated structural fire barriers that help block the spreading of hazardous fire and smoke by compartmentalizing a building space and keeping the event isolated. Many buildings today mandate the placement of rolling steel fire doors as a standard safety precaution.
The Firemiser Insulated Rolling Fire Door is perfect for an exterior application and reduces sound transfer thanks to mineral wool insulation. Mineral wool insulation also minimizes thermal transfer, which can help you with temperature control inside your building. Opt for the SmokeShield™ seal package for your fire-rated door if you’re required to conform to UL 1784 or want an additional barrier to eliminate smoke migration throughout your building.
Areas of assembly – arenas, ballrooms, houses of worship, performing arts, recreation facilities and restaurants
Areas of refuge – elevator lobbies and stairwells
Areas of separation – cross corridor
Paths of egress – building exits and ground floor stairwells
Single doors, pairs and double egress pairs found in the following applications:
BENEFITS
Tested Durability
- Heavy-wall aluminum construction
- Pushbar holds retracted when the door is in the open position, maximizing the clear opening width and limiting damage
Enhanced Security
Patented friction-limiting latch bolt with 7/8″ throw
Available in top latching or top and bottom latching
Exterior lever with anti-abuse clutching
Protected latches and operating mechanisms are concealed within the steel door and sheltered from attack, abuse, or tampering
Versatility
- Extensive list of ANSI functions to suit most openings and applications
- Access control ready with latch retraction, electrified lever and RX options
- Electrical options available in kit-form allowing for future upgrades
Uncompromised Safety
- Listed for flush Panic Hardware (UL305) and for fire tests (UL10C) with single-point top latching or top and bottom latching
- Pushbar holds retracted when the door is in the open position maximizing the clear opening
- Top latching instead of side edge latchbolt and strike for singles and pairs prevents catching on clothing or equipment
- Optional antimicrobial coatings available for healthcare, education and other germ-sensitive environments
- CleanVue – Simple hygienic release feature allows for full access to the pushbar for sanitizing without disassembly
Unequaled Aesthetics
- Minimized pushbar end caps with hidden fasteners provides clean, uninterrupted lines
- Pushbar available in architectural and décor-matching finishes
- Escutcheon-free levers available in the most popular styles and finishes
- Décor Series levers used to make a unique design statement, or to match other locksets used on a project
- Optional integrated top strike prep eliminates the need for a surface mounted auxiliary plate
- Projection type latchbolt minimizes the top strike view and minimizes the top door “notch” required by others
- No floor strikes required means fire ratings without the need for bottom latchbolts
Lever Options
If our standard levers don’t match your style preferences please ask about our Décor Lever Series.

Hardware finish options
Antimicrobial coatings are available for healthcare, education and other germ sensitive environments.

Model Number | ANSI Function Description | Description |
---|---|---|
XT | 01 | Exit Only, no trim. |
XT-LC | 03 | Entrance by fixed lever/pull - latch released by key. Key removable when locked (Nightlatch). |
XT-LC | 08 | Entrance by lever. Key locks or unlocks lever. |
XT-LC | 09 | Entrance by lever. Key removable when locked (Nightlatch). |
XT-LC2 | 10 | Entrance by lever. Inside or outside key locks or unlocks lever. Outside key releases latch. |
XT-C | 13 | Entrance by key. |
XT-L | 14 | Entrance by lever. Always active, no cylinder. |
Device Functions | Configured from the factory. See Function Chart for description. |
---|---|
Fire Ratings | Listed for Panic Hardware (UL305) and for positive pressure fire tests (UL10C) with single-point top latching or top and bottom latching. |
Pushbar Height | 4” |
Pushbar Width | 15 ¼" (387 mm) for 24" to 29-15/16" openings | 18 ¼" (464 mm) for 30" to 35-15/16" openings | 24 ¼" (641 mm) for 36" to 41-15/16" openings | 30 ¼" (768 mm) for 42" to 51" openings |
Pushbar Projection - Extended | 1-3/16" (30 mm) |
Pushbar Projection - Depressed or with Door Held Open | 3/16" (5 mm) |
Pushbar Centerline | 38-1/2" (978 mm) from structural floor (not including floor covering). |
Pushbar Materials | 6063-T6 Extruded Aluminum with finish inserts. |
Strikes | Top strike can be mortised or surface applied (P/N TSK-1 Kit). Bottom strike, if applicable, is a ½” diameter hole threshold or surface strike (P/N BSK-1 Kit). |
Electrical Options | RX – Request to Exit. Provides a switch closure when the exit device is actuated. - RX2 – Same as above with two independent SPST switches. |
ML - Motorized latch retraction quietly and efficiently retracts the latch(es) and pushbar when energized. Configured for fail-secure to comply to fire ratings. | |
LM - Latchbolt monitoring provides notification when the latch is extended. | |
ELS - Electrified lever. Energizing allows lever to rotate to retract the latch(es). Fail-Secure or Fail-Safe available. | |
Mounting | Concealed fasteners on pushbar end caps, latches and handles. |
Latchbolts | Top latching standard with – 7/8" (22.2 mm) throw. Projection type - friction limiting-design with deadlatch feature. Bottom – Stainless Steel 5/8" throw bolt with conical tip. |
Optional Keyed Cylinder | Standard diameter Mortise Cylinder with 'standard' cam. Accepts 1" cylinder length or greater. Cylinder in excess of 1” requires a spacer collar equal to this excess (Example 1-1/8" length requires a 1/8" collar). |
Function 10 - Back-to-back Cylinders | Requires a 3/16" collar for a 1" cylinder length. For longer cylinders, use the following to dimension the collar: Cylinder Length –1” + 3/16”= Collar (Ex. 1-1/4" requires a 7/16” collar). |
HARDWARE SPECIFICATIONS
Brochures
This product is not available in Quebec. Therefore some of the following downloads may not be available in French.
This Product in action



