Bravura Architectural Products Whitby
Kalwall

Specialty Applications

Hurricane rated walls and windows

Kalwall Specialty Applications Whitby

High impact options

Kalwall Specialty Applications Oshawa

Class A fire ratings

Kalwall Specialty Applications Durham Region

Blast resistant systems meet DOD UFC 4-010-01 Anti-Terrorism Force Protection (ATFP)

Kalwall Specialty Applications Toronto

Factory Mutual certified systems: Class I Exterior Wall FM 4881 & FM 4411

Kalwall Specialty Applications Mississauga

Factory Mutual explosion venting/pressure relief system: FM 4440

Kalwall Specialty Applications Markham

Bespoke designs

Kalwall Facade Systems can be custom engineered to meet a variety of specialty applications including:
Kalwall Specialty Applications Ontario

TECHNICAL INFORMATION

downloads and details

Thermally Broken Wall Systems

2-3/4" (70mm) Standard Thickness

For more demanding climate zones and building types. Thermally-Broken Wall systems provide enhanced envelope performance to meet or exceed the toughest energy codes.

Thermally-broken, interlocking I-beam panel grid core

Thermally-broken aluminum Clamp-tite™ fastening system

U-factors range from 0.23 - 0.05 (1.31 to 0.28 W/㎡K)

Solar Heat Gain Coefficients (SHGC) from 0.36 to 0.04

Visible Light Transmission (VLT) values from 3% to 35%

THERMAL BREAK+STRUCT SYSTEM | BACK FASTENED SYSTEM | CONCEALED FASTENERS | KALWALL 100 (4" SYSTEM)

Standard Wall Systems

2-3/4" (70mm) Standard Thickness

For certain climate zones and building types, non thermally-broken Wall Systems provide sufficient envelope performance that is both cost effective and meets energy codes.

Standard, aluminum interlocking I-beam panel grid core

Standard aluminum Clamp-tite™ fastening system

U-factors range from 0.53 - 0.18 (3.01 to 1.02 W/㎡K)

Solar Heat Gain Coefficients (SHGC) from 0.65 to 0.10

Visible Light Transmission (VLT) values from 3% to 58%

STANDARD SYSTEM | BACK FASTENED SYSTEM | CONCEALED FASTENERS | KALCURVE | 1-9/16" SYSTEM

Specialty Applications

2-3/4" (70mm) Standard Thickness

Kalwall offers many product configurations for projects that require special performance criteria to protect from extreme weather events and manage human safety+security.

Class A fire ratings available for Wall Systems and Unitized Curtain Walls

Windborne debris protection - tested and certified up to large missile D

Blast resistant systems meet DOD UFC 4-010-01 anti-terrorism force protection

Factory Mutual certified systems: Class I exterior wall FM 4880 & FM 4881

Factory Mutual explosion venting pressure realease systems: FM 4440

WIMBORNE DEBRIS PROTECTION | EXPLOSION VENTING | ANTI-TERRORISM FORCE PROTECTION | FM CLASS I

This Product in action

Kalwall Specialty Applications Vaughan
Kalwall Specialty Applications Hamilton
Kalwall Specialty Applications Burlington
Kalwall Specialty Applications Kingston
Share by: