Bravura Architectural Products Whitby
Smoke Guard

Elevator Smoke Containment – Standard

In combination with the fire-rated doors used in nearly all elevators, our elevator smoke containment curtains provide comprehensive and code-compliant smoke and draft opening protection. These units are easy to install in elevator openings and integrate seamlessly with existing fire protection systems to quickly bring a structure up to code.

Smokeguard Elevator Smoke Containment – Standard Kingston

TECHNICAL INFORMATION

downloads and details

Customer-Favourite Commercial Rollup Doors

Depending on your needs, we have an extensive selection of high-performance, energy-efficient and fire-rated products to choose from, including the following.

SECURE ROLLUP GARAGE DOORS

If you want top performance and high-speed operation, our high-performance security doors will have you covered. These doors are among the best overhead door investments with some of the lowest overall lifetime costs:

  • Extreme® 300 Series High-Performance Rollup Door: This springless series door is high-speed and intelligent thanks to the Apex SmartController. Designed to last 300,000 maintenance-free cycles, the Extreme 300 has it all.
  • Extreme® 1024 Long-Lasting Rollup Door: The Extreme 1024 high-performance rapid-roll door offers intelligent Apex SmartController operation and can withstand an impressive 1,000,000 maintenance-free cycles.
  • StormDefender™ Safe Room Door: This commercial rollup door is designed explicitly with security and life safety in mind, guarding you and your building against tornadoes, hurricanes and other severe weather.
  • EntryDefender™ High-Security Door: The EntryDefender™ Door meets the U.S. Department of State Standard for forced entry for a five-, 15- and 60-minute mob-style attack.
FIRE-RATED ROLLUP SERVICE DOORS

Rollup fire doors are rated structural fire barriers that help block the spreading of hazardous fire and smoke by compartmentalizing a building space and keeping the event isolated. Many buildings today mandate the placement of rolling steel fire doors as a standard safety precaution.



The Firemiser Insulated Rolling Fire Door is perfect for an exterior application and reduces sound transfer thanks to mineral wool insulation. Mineral wool insulation also minimizes thermal transfer, which can help you with temperature control inside your building. Opt for the SmokeShield™ seal package for your fire-rated door if you’re required to conform to UL 1784 or want an additional barrier to eliminate smoke migration throughout your building.

Not sure which elevator curtain is the best for your product?

Try out our Product Selector.

Elevator hoistway opening sizes
  • M200: 42” and 48” only
  • M400: up to 60” wide


Ceiling Height
  • M200: Up to 10 feet high
  • M400: Up to 10 feet high standard, up to 12 feet high custom (4’7″ wide x 12′ tall)


Unit return sizes (projection from wall)
  • M200: 1 inch
  • M400: 1/2, 3/4, and 1 inch


Housing dimensions
  • M200: Housing Lengths: 55 and 64 inches • Height: 10.5 inches • Depth: 9 inches (plus return)
  • M400: Housing Lengths: 55, 64, and 73 inches • Height: 10.5 inches • Depth: 9 inches (plus return)


Unit electronic control

Integrated and located in housing of the unit.


Emergency power source

M400 units may be specified with an internal, FCC compliant, battery backup system. This feature is not available in M200 units. Both models may be connected to emergency power.


Protection from temporary power failures

M200 and M400: A brief delay avoids nuisance deploys.


Screen rewind switch

Yes, located on both sides of curtain.


Screen deploy switch

M200 and M400: Yes, located on controls inside housing.


Stainless steel auxiliary rails
  • M200: Auxiliary rails are standard.
  • M400: Rails optional, if elevator frame is ferrous and at least 2″ wide.

This product is not available in Quebec. Therefore some of the following downloads may not be available in French.

This Product in action

Smokeguard Elevator Smoke Containment – Standard Brampton
Smokeguard Elevator Smoke Containment – Standard Cornwall
Smokeguard Elevator Smoke Containment – Standard Ottawa
Smokeguard Elevator Smoke Containment – Standard London
Share by: