a

Specialty Applications – Kalwall

Kalwall Facade Systems can be custom engineered to meet a variety of specialty applications including:

  • Hurricane rated walls and windows
  • High impact options
  • Class A fire ratings
  • Blast resistant systems meet DOD UFC 4-010-01 Anti-Terrorism Force Protection (ATFP)
  • Factory Mutual certified systems: Class I Exterior Wall FM 4881 & FM 4411
  • Factory Mutual explosion venting/pressure relief system: FM 4440
  • Bespoke designs
  • Kalwall Specialty Applications

    Technical Information

    Specialty Applications | 2-3/4" (70mm) Standard Thickness
    Kalwall offers many product configurations for projects that require special performance criteria to protect from extreme weather events and manage human safety+security
    Class A fire ratings available for Wall Systems and Unitized Curtain Walls
    Windborne debris protection - tested and certified up to large missile D
    Blast resistant systems meet DOD UFC 4-010-01 anti-terrorism force protection
    Factory Mutual certified systems: Class I exterior wall FM 4880 & FM 4881
    Factory Mutual explosion venting pressure realease systems: FM 4440
    WINDBORNE DEBRIS PROTECTION | EXPLOSION VENTING | ANTI-TERRORISM FORCE PROTECTION | FM CLASS I
    Thermally Broken Wall Systems | 2-3/4" (70mm) Standard Thickness
    For more demanding climate zones and building types. Thermally-Broken Wall systems provide enhanced envelope performance to meet or exceed the toughest energy codes.
    Thermally-broken, interlocking I-beam panel grid core
    Thermally-broken aluminum Clamp-tite™ fastening system
    U-factors range from 0.23 - 0.05 (1.31 to 0.28 W/㎡K)
    Solar Heat Gain Coefficients (SHGC) from 0.36 to 0.04
    Visible Light Transmission (VLT) values from 3% to 35%
    THERMAL BREAK+STRUCT SYSTEM | BACK FASTENED SYSTEM | CONCEALED FASTENERS | KALWALL 100 (4" SYSTEM)
    Standard Wall Systems | 2-3/4" (70mm) Standard Thickness
    For certain climate zones and building types, non thermally-broken Wall Systems provide sufficient envelope performance that is both cost effective and meets energy codes.
    Standard, aluminum interlocking I-beam panel grid core
    Standard aluminum Clamp-tite™ fastening system
    U-factors range from 0.53 - 0.18 (3.01 to 1.02 W/㎡K)
    Solar Heat Gain Coefficients (SHGC) from 0.65 to 0.10
    Visible Light Transmission (VLT) values from 3% to 58%
    STANDARD SYSTEM | BACK FASTENED SYSTEM | CONCEALED FASTENERS | KALCURVE | 1-9/16" SYSTEM

    LIKE WHAT YOU SEE?

    Connect with us for partnerships, new projects and inquiries.

      English